Features of Products As one kind of distributing transformer for mining use, KS9 series
transformer has many advantages, such as compacted body, reasonable structure, Iow in spoilage, good in heat-dispersion and,
easy to go into a well. This series of product adopt high-permeance cold-rolled
grain-oriented silicon-steel plate of high-quality. The iron core
applies echelon form iterative accumulation. The core pole which is
multilevel circular cross-section can ensure of Iow noise and Iow
spoilage. The structure of gasoline tank is very firm. Both side of tank are
welded with cable junction boxes of high and Iow voltage which are used for wiring. High-voltage loops need tapping voltage that is
±5% of rated voltage. It is using the tap switch to change the
voltage. When the voltage exchanges, the power must be cut off fist, then
unveil the wind-rain cover on the tap switch to counterchange the voltage. The Iow voltage side of the transformer can be connect the
type’Y’ of 693V or the type "D" of 400V to supply power. And inside the cable junction box has a secondary terminal which educes
six insulators for users’ option. The joint hinges that welded on the casing are available and drawing crow-plate is mounted
beneath the base. There are mounting holes in the drawing
crow-plate used for being addly-installed with mine-car’ contact roller
whenmine needing.
Practicable ConfinesThe oil-immersed distributing transformer is applied to the
capacity 630KVA or below, and the voltage 10KV or below. This product is normal one which has norequirement
of explosion - proof. The main function of the product is for mine illumination when distributing power for
mining as well as for the driving power. This series of transformers will not need lift-machine examination
after transportation. It is allowed to assemble the unshipped spare parts for checking and acceptance. Comply Standards Standards for this series of product: GB1094.1~2-1996, GB1094.3,5-2003, GB/T6451-1999, GB12173-1990o
Using environment and working condition 1、The installment highly does not surpass elevation 1000m,the
special environment gives the explanation in addition; 2、Ambient temperature: Highest air temperature +40℃; Highest daily average air temperature+25℃; Highest annual average air tempera ture+20℃; Lowest outdoor air temperature-20℃. 3、The surrounding air relative hurnidityis not bigger than 95%
(+25℃when. 4、Installs under the mine pit although has the coal dust, the gas
,but non-explosion hazard place; 5、The supply voltage profile is approximate to the sine wave;
Type MeaningTech data of KS9 series electric transformer |
rated capacity (kVA) | Voltagegroup (kv) | connection method | Loss | no-load current | impedance voltage | weight | outline dimension | | no-load | load | machine weight | oil weight | gross weight | | 50 | 10 6 0.693/0.4 | Yy0-d11 | 0.17 | 0.87 | 2.0 | 4 | 230 | 80 | 390 | 1200*950*900 | | 80 | 0.25 | 1.25 | 1.8 | 310 | 100 | 530 | 1300*950*950 | | 100 | 0.29 | 1.50 | 1.6 | 360 | 110 | 600 | 1300*950*1000 | | 125 | 0.34 | 1.80 | 1.5 | 425 | 120 | 690 | 1300*950*1000 | | 160 | 0.40 | 2.20 | 1.4 | 480 | 140 | 810 | 1350*950*1040 | | 200 | 0.48 | 2.60 | 1.3 | 580 | 170 | 955 | 1400*970*1080 | | 250 | 0.56 | 3.05 | 1.2 | 670 | 180 | 1100 | 1450*1000*1100 | | 315 | 0.67 | 3.65 | 1.1 | 775 | 240 | 1305 | 1500*1 |
|